Beurer LW 110 User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
16
Clean the water level sensor
You can clean the lower half of the water level sensor in a cleaning bath. Ensure that the upper half of the
water level sensor is not exposed to any harsh cleaning products. The water level sensor must not be cleaned
in the dishwasher.
Descaling the humidification discs and the tub
Depending on water hardness and if necessary, the tub and humidification discs must be descaled in order
to maintain the performance of the air washer.
For this purpose, use a standard descaling agent and observe the information on the label.
Note: A light build-up of limescale on the humidification discs increases the evaporation effect.
Storage
If you do not plan to use the device for a relatively long period of time, we recommend that you thoroughly
empty, clean and dry the device and store it in the original packing in a dry environment, ensuring it is not
weighed down by additional items.
8. What if there are problems?
Problem Cause Solution
No display. The device is not connected to
mains power supply.
Connect the mains plug and switch on
the device.
No display. The device has switched itself off
due to safety reasons.
Clean and refill the device before next
use. Then switch it on again.
The upper cover cannot be
fitted precisely.
The guide rails do not fit and the
upper cover is jammed.
Turn the upper cover around by 180°
and reposition it on the tub.
The water level gauge
always shows the same fill
level despite differing water
levels.
The fill level sensor is dirty. Remove the upper cover from the tub,
unlock the water level sensor, remove
it and clean carefully.
9. Replacement parts
Only use original parts and from the manufacturer.
10. LW 110 technical data
Dimensions (L x W x H) 30 x 30 x 34 cm
Cable length approx. 2 m
Weight when empty approx. 6 kg
Power supply unit. 220 – 240 Volt/50 60 Hz
Output 38 Watt
Suitable for rooms up to approx. 36 m²
Maximum capacity approx. 7.25 litres