Browse online or download User Manual for Health and hygiene Beurer GL 42 (mg/dL). Beurer GL 42 (mg/dL) User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
germanlengineering
Beurer GmbH
Söflinger Straße 218
89077 Ulm, Germany
www.beurer.com
instructions for use
GL42
GB
mg/dL
BLOOD GLUCOSE MONITOR
Step by Step
Codefree
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - Codefree

germanlengineeringBeurer GmbH • Söflinger Straße 218 • 89077 Ulm, Germanywww.beurer.cominstructions for useGL42GBmg/dLBLOOD GLUCOSE MONITORStep by St

Page 2

10 Beurer GL42 mg/dLRepairs Note•Do not open the device. Failure to comply will result in voiding of the warranty.•Do not repair the device. Prope

Page 3 - Contents

Beurer GL42 mg/dL 113. description of units and accessories3.1 Blood glucose monitorFront1. Slot for test strips2. Rocker switch “+”, “-”3. Displ

Page 4

12 Beurer GL42 mg/dL3.2 Display symbols 1. Date 2. Symbols for highlighting measured values 3. Measured value display, display , , Averag

Page 5

Beurer GL42 mg/dL 13Insert the test strip into the device so that the contacts are pointing inside the slot.Make sure that the front of the test stri

Page 6 - 1.3 Signs and symbols

14 Beurer GL42 mg/dL4. initial use and basic settinGs4.1 Removing the battery insulation strips, replacing the battery Note• Remove the insulation

Page 7 - Itemno

Beurer GL42 mg/dL 153Switching the acoustic signal on/oTo switch the acoustic signal o, press the “+” or “–” button.“ ” and “ ” is displayed.The sp

Page 8

16 Beurer GL42 mg/dLHighlighting measured valuesYou have the following options to highlight measured values.Before meals.After meals.General highligh

Page 9

Beurer GL42 mg/dL 17Evaluating critical measured valuesDisplay Blood glucose ActionVery low blood glucose levelBelow 20 mg/dLSeek medical attention i

Page 10

18 Beurer GL42 mg/dL Important • Do not use third-party control solution. Correct functioning of the measuring device can only be tested using the Be

Page 11 - 3V

Beurer GL42 mg/dL 195Hold the input gap (at the tip of the test strip) to the drops of control solution until the gap is completely filled and the mea

Page 13

20 Beurer GL42 mg/dL WarningDo not use the system to measure your blood glucose level if you are repeatedly provided with measurements outside the sp

Page 14

Beurer GL42 mg/dL 213Pressing the rocker switch “–” [2] will display the previous measured value each time. You can display a maximum of 480 previous

Page 15 - 5.1 Evaluating the result

22 Beurer GL42 mg/dL2Press “+” [2] repeatedly to display the average value of all measured values for 14, 30 and 90 days.After the average of all mea

Page 16

Beurer GL42 mg/dL 232After displaying the average value for 90 days “after meals” • the average for the last seven days of values highlighted as “ge

Page 17

24 Beurer GL42 mg/dL3The device then indicates that the subsequent measured value has moved to the memory space of the deleted measured value.7.5 De

Page 18

Beurer GL42 mg/dL 25• Protect the device from damaging factors such as moisture, dirt, dust, blood, control solution or water, marked temperature fluc

Page 19

26 Beurer GL42 mg/dLProblem: device does not switch onCause SolutionEmpty battery. Replace battery.Incorrectly inserted or missing batteries.Check wh

Page 20

Beurer GL42 mg/dL 2710. technical specifications Dimensions (L x W x H) 88 x 51 x 15 mmWeight 41g incl. batteryPower supply 1 x 3 V CR 2032 button c

Page 21

28 Beurer GL42 mg/dLamount of blood is required (0.6 microlitres) and measurement duration is approx. five seconds. The test strip detects blood gluco

Page 22

Beurer GL42 mg/dL 29Results of the intermediate precision measurementSample Control material (mg/dL)Grand mean value (mg/dL)Pooled standard deviation

Page 23

Beurer GL42 mg/dL 3Contents1. Getting to know your instrument...41.1 De

Page 24 - 8.2 Disinfection

30 Beurer GL42 mg/dLPerformance evaluation by the userA study to assess the glucose values of blood samples of capillary blood from the fingertips, wh

Page 25

Beurer GL42 mg/dL 31

Page 26

751.178-0314_GL42_mg/dL_GB Subject to errors and changes

Page 27

4 Beurer GL42 mg/dL1. GettinG to know your instrumentDear customer,Thank you for choosing one of our products. Our name stands for high-quality, thor

Page 28

Beurer GL42 mg/dL 51.1 Delivery scope, replacements and accessoriesCheck that the set packaging has not been tampered with and make sure that all co

Page 29

6 Beurer GL42 mg/dLFollow-up purchasesYou can also obtain test strips, control solution and lancet needles without a prescription.Item REF PIP German

Page 30

Beurer GL42 mg/dL 7Maximum shelf life after initial opening in monthsContents sucient for <n> testsBatch designation /Itemno.Order numberSter

Page 31 - Beurer GL42 mg/dL 31

8 Beurer GL42 mg/dLGeneral notes WarningDo not use the device in the vicinity of strong electromagnetic fields and keep it away from radio systems or

Page 32

Beurer GL42 mg/dL 9• Very high levels of humidity may influence the test results. Relative humidity of more than 90% may lead to inexact results. Not

Comments to this Manuals