Do not inflate the cuff unless wrapped around wrist.
If no button is pressed for approx. 1 minute the automatic
shut off function shuts off the unit in order to preserve the
batteries.
Do not touch the unit and cuff and/or press any buttons
when measurement is in progress, except for stopping the
measurement. Doing so may cause incorrect readings.
5.4 Taking Measurement
NOTE:
If you are using the unit for the first time, please remove the
protective film from the display.
Put on the cuff around your bare left wrist as described
previously and assume the position in which you want to
carry out the measurement.
Start the blood pressure monitor with the start/stop but-
ton . A beep and a brief display of all the symbols con-
firm that the device is switched on.
Before the measurement, the last saved test result is briefly
displayed. If there is no measurement in the memory, the
instrument always displays the value “0”.
The cuff is pumped up to 190 mmHg. Cuff air pressure
is released slowly, the pulse symbol
is flashing and
the pulse is measured. As the cuff deflates, decreasing
numbers appear on the display.
If a tendency towards high blood pressure is already de-
tectable, the cuff is pumped up again and cuff pressure
increased further. The pulse symbol
flashes as soon
as a pulse is found.
After the pressure has been completely reduced, the sys-
tolic pressure, diastolic pressure and pulse readings are
displayed.
Measuring can be interrupted at any time by pressing the
start/stop button .
“Er_” appears if it has not been possible to perform the
measurement properly. See section 8. on error messages/
troubleshooting and repeat the measurement.
The test result is saved automatically.
To switch off press the start/stop button again. If you
forget to switch off the device, it switches off automati-
cally after approx. 1 minute.
Wait at least 5 minutes before taking another measure-
ment.
6. Evaluating results
WARNING:
This product does not and is not intended to provide a
medical diagnosis. Measurements results are for refer-
ence only. Self-diagnosis and treatment, e.g. regarding
medication, using measured results represent a risk for
your health. Always consult with a licensed physician